  1. PX5202M

    Model: PX5202M
    Kataloški broj: 30430027
    Odobren model (kod Direkcije za mere i dragocene metale): Da, Klasa II
    Verifikacioni interval (e) (g): 0,1
    Kalibracija: Interna
    Kapacitet (g): 5200
    Rezolucija (g): 0,01
    Ponovljivost (STDEV) (g): 0,01
    Linearnost (g): ± 0,02
    Vreme stabilizacije (s): 1
    Osetljivost temperaturnog odstupanja (PPM/K): ± 3
    Tipična minimalna masa merenja prema USP (USP K=2, U=0,10%): 20 g
    Optimizovana minimalna masa merenja (USP, U=0,10%, K=2) SRP≤0,41d*: 8,2 g
    Jedinice merenja: g, mg, ct
    Aplikacije: Osnovno merenje mase, Brojanje komada, Procentulano merenje, Merenje životinja, Određivanje gustine
    Dimenzije merene ploče (Ø): 180 mm
    Napajanje: Ulaz: 100-240V; 200mA 50-60Hz 12-18VA, Izlaz: 12VDC 0,5A
    Dimenzije vage (Š x D x V): 209 x 321 x 98 mm
    Komunikacioni interfejsi: RS232 i USB
    Opseg radne temperature: 10°C do 30°C
    Neto težina: 3,5 kg
    Težina transportnog pakovanja: 5 kg
    Dimenzije transportnog pakovanja (Š x D x V): 550 x 385 x 291 mm

    IQ/OQ/PQ Kvalifikacija: Da, moguća je

    *: Vrednost SRP je standardna devijacija za n broj merenja (n≥10)
  2. PX323

    Model: PX323
    Kataloški broj: 30429805
    Odobren model (kod Direkcije za mere i dragocene metale): Da
    Kalibracija: Interna
    Kapacitet (g): 320
    Rezolucija (g): 0,001
    Ponovljivost (STDEV) (g): 0,001
    Linearnost (g): ± 0,002
    Vreme stabilizacije (s): 2
    Osetljivost temperaturnog odstupanja (PPM/K): ± 3
    Tipična minimalna masa merenja prema USP (USP K=2, U=0,10%): 2 g
    Optimizovana minimalna masa merenja (USP, U=0,10%, K=2) SRP≤0,41d*: 0,82 g
    Jedinice merenja: Milligram, Gram, Kilogram, Ounce, Pound, Carat, Pennyweight, Ounce Troy, Grain, Newton, Hong Kong Tael, Singapore Tael, Taiwan Tael, Momme, Tical (MM), Mesghal, Tola (India), 1 Custom unit
    Aplikacije: Osnovno merenje mase, Brojanje komada, Procentulano merenje, Merenje životinja, Određivanje gustine
    Dimenzije merene ploče (Ø): 120 mm
    Napajanje: Ulaz: 100-240V; 200mA 50-60Hz 12-18VA, Izlaz: 12VDC 0,5A
    Dimenzije vage (Š x D x V): 209 x 321 x 309 mm
    Komunikacioni interfejsi: RS232 i USB
    Opseg radne temperature: 10°C do 30°C
    Neto težina: 4,5 kg
    Težina transportnog pakovanja: 7 kg
    Dimenzije transportnog pakovanja (Š x D x V): 507 x 387 x 531 mm

    IQ/OQ/PQ Kvalifikacija: Da, moguća je

    *: Vrednost SRP je standardna devijacija za n broj merenja (n≥10)
  3. PX224

    Model: PX224
    Kataloški broj: 30429804
    Odobren model (kod Direkcije za mere i dragocene metale): Da
    Kalibracija: Interna
    Kapacitet (g): 220
    Rezolucija (g): 0,0001
    Ponovljivost (STDEV) (g): 0,0001
    Linearnost (g): ±0,0002
    Vreme stabilizacije (s): 4
    Osetljivost temperaturnog odstupanja (PPM/K): ± 3
    Tipična minimalna masa merenja prema USP (USP K=2, U=0,10%): 200 mg
    Optimizovana minimalna masa merenja (USP, U=0,10%, K=2) SRP≤0,41d*: 82 mg
    Jedinice merenja: Milligram, Gram, Kilogram, Ounce, Pound, Carat, Pennyweight, Ounce Troy, Grain, Newton, Hong Kong Tael, Singapore Tael, Taiwan Tael, Momme, Tical (MM), Mesghal, Tola (India), 1 Custom unit
    Aplikacije: Osnovno merenje mase, Brojanje komada, Procentulano merenje, Merenje životinja, Određivanje gustine
    Dimenzije merene ploče (Ø): 90 mm
    Napajanje: Ulaz: 100-240V; 200mA 50-60Hz 12-18VA, Izlaz: 12VDC 0,5A
    Dimenzije vage (Š x D x V): 209 x 321 x 309 mm
    Komunikacioni interfejsi: RS232 i USB
    Opseg radne temperature: 10°C do 30°C
    Neto težina: 4,5 kg
    Težina transportnog pakovanja: 7 kg
    Dimenzije transportnog pakovanja (Š x D x V): 507 x 387 x 531 mm

    IQ/OQ/PQ Kvalifikacija: Da, moguća je

    *: Vrednost SRP je standardna devijacija za n broj merenja (n≥10)
  4. PX124

    Model: PX124
    Kataloški broj: 30429803
    Odobren model (kod Direkcije za mere i dragocene metale): Da
    Kalibracija: Interna
    Kapacitet (g): 120
    Rezolucija (g): 0,0001
    Ponovljivost (STDEV) (g): 0,0001
    Linearnost (g): ±0,0002
    Vreme stabilizacije (s): 4
    Osetljivost temperaturnog odstupanja (PPM/K): ± 3
    Tipična minimalna masa merenja prema USP (USP K=2, U=0,10%): 200 mg
    Optimizovana minimalna masa merenja (USP, U=0,10%, K=2) SRP≤0,41d*: 82 mg
    Jedinice merenja: Milligram, Gram, Kilogram, Ounce, Pound, Carat, Pennyweight, Ounce Troy, Grain, Newton, Hong Kong Tael, Singapore Tael, Taiwan Tael, Momme, Tical (MM), Mesghal, Tola (India), 1 Custom unit
    Aplikacije: Osnovno merenje mase, Brojanje komada, Procentulano merenje, Merenje životinja, Određivanje gustine
    Dimenzije merene ploče (Ø): 90 mm
    Napajanje: Ulaz: 100-240V; 200mA 50-60Hz 12-18VA, Izlaz: 12VDC 0,5A
    Dimenzije vage (Š x D x V): 209 x 321 x 309 mm
    Komunikacioni interfejsi: RS232 i USB
    Opseg radne temperature: 10°C do 30°C
    Neto težina: 4,5 kg
    Težina transportnog pakovanja: 7 kg
    Dimenzije transportnog pakovanja (Š x D x V): 507 x 387 x 531 mm

    IQ/OQ/PQ Kvalifikacija: Da, moguća je

    *: Vrednost SRP je standardna devijacija za n broj merenja (n≥10)
  5. ASP-6

    Model: AAP-6
    Test Methods: ASTM D36, ASTM E28, EN 1427, IP 58, etc
    Type: Two-rings & two-balls
    Measuring Range: Ambient to 200?C (392?F )
    Temperature Sensor: PT-100 in stainless steel sheath
    Softening Point Detector: Light projector: LED; Light receiver: photo-diode
    Display: 5.7" color LCD with back light
    Heater: Nichrome coil heater: 1,000W @100V or 1,000W @220V
    Sequense Control: By an on-board microcomputer
    Test Mode: ASTM D36 water, ASTM D36 glycerin, EN 1427 water, EN 1427 glycerin
    Stirring: Magnetic stirring, selectable from 0 to 250 rpm
    I/O Port: 1x Ethernet for LIMS; 1x USB for Flash Memory or Keyboard; 1x RS-232C for LIMS / PC or Optional Printer
    Data Memory: Last 200 sets of test results
    Safety Mechanism: a) The sample falls on only one side and not on the other within the set temperature range, b) The sample does not fall on either side within the set upper limit temperature, c) Light projector or receiver is found defective, d) Temperature sensor is found defective, e) Temperature sensor is not placed in the right position, f) Built-in battery is found drained out, or g)Control computer runs away (no display)
    Size (WxDxH): 230 x 470 x 440 (mm)
    Weight: 15 kg
    Ambiental Conditions: RT: 10 to 40?C, RH: Less than 90% (no condensation)
    Power Supply: AC100/120 V or 220/240V 50/60Hz (set at the factory, specify when ordering) 1,500W ( max.)

    IQ/OQ/PQ Qualification: Yes, possible
  6. AAP-6

    Model: AAP-6
    Conforming Standards: ISO2977, ASTM D611, etc.
    Measuring Range: Ambient +20°C to 170°C, for bellow ambient temperature + 20°C, the optional water jacketed measuring cell and a cryostat must be used.
    Temeprature Sensor: Pt100 in stainless steel sheath
    Aniline Point Detector: Photo-electric cell with special detection circuitry
    Measuring Cell: Modified U-Tube type, vacuum jacketed glass cell with PTFE stopcock at the bottom for drainage.
    Display: 5,7" color LCD with LED backlight
    Heater: Immersion heater in stainless steel sheath: 20W
    Sequense Control: By an on-board microcomputer
    Test Mode: Sinle, repeat (2 kinds, average is reported to nearest 0,05°C), SPE and manual temp set
    I/O Port: 1x Ethernet for LIMS, 1x USB for Flash memory or keyboard, 1x RS-232C for PC or optional printer
    Safety Mechanism: Automatically shuts off and the problem is reported by buzzer and display in case: a) EAP+10°C or 170°C is reached, b) Temperature sensor is found defective, c) Light projector or receiver is found defective, d) Built in battery is found drained out, e) Control computer runs away (no display)
    Dimensions (W X D X H): 230 x 470 x 490 mm
    Weight: 14Kg
    Ambiental Conditions: 10 to 40°C, Relative Humidity less than 90%
    Power Supply: AC 100 to 240V; 50/60Hz; 125W max

    IQ/OQ/PQ Qualification: Yes, possible
  7. AKV-202

    Model: AKV-202
    Type: Bench top automatic KV measuring system with 2 viscometers in 1 bath
    Related Standards: ISO 3104, ASTM D445, IP71, etc.
    Viscometers: Modified Lanz-Zeitfuchs viscometers
    Measuring Range: 10,000 mm2 /s for automatic operation. (Range depends on viscometer.)
    Meniscus Detection: By photo-electric devices with fiber optics
    Timing: 0.00 - 999.99 sec
    Bath: Stainless Steel bath with drain, 18 liters
    Bath Heater: Sheathed heaters, 0.59kW x2
    Bath Lighting: Fluorescent light, 6W
    Bath Medium: Water (distilled or ion exchanged) for < 75°C, Colorless/transparent silicon oil (with PMCC flash point of 190°C at minimum and KV of 10-20mm2/s) for >= 75°C.
    Bath Temperature Controller: Temp: Preset at 6 points. Preset point can be set at any temp between 20 and 100°C; Precision: ±0.01°C
    Cleaning/Drying Viscometers: An automatic cycle consisting of draining sample, injecting chemicals, and drying with air. By vacuum; Chemicals: BTX for cleaning, Ethanol ?Bath Temp <80°C?for drying. (Ether or Ketone can not be used); Fume: Fume to be exhausted through trap and hose to outside
    Display: Test parameters, status, trouble, etc. displayed on fluorescence display module
    Printer: Thermal printer, 58mm of paper width
    Computer Output: RS-232C, 1 channel
    Safety: Alarms for gas, bath medium level, & bath overheat
    Power Requirements: 100, 120, 220 or 240VAC, 2 KW
    Dimension & Weight (Wxdxh): 530mm x 560mm x 930mm, 75kg

    IQ/OQ/PQ Qualification: Yes, possible
  8. AVP-30D4

    Model: AVP-30D4
    Related Standards: ISO 3007, ASTM D323, IP69 etc.
    Type: Bench-top automated instrument. Automated continuous shaking of test cylinder by "seesaw" motion.
    Number Of Cylinders (Measurement Spots): 4
    Measuring Range: 0 to 196 kPa (2 kgf/cm2)
    Test Cylinders: Small size stainless steel cylinders with 66% in length and 31% in volume compared to the regular full size cylinders. The V/L ratio of 4 is the same as full size cylinder. A "Quick Coupler" is equipped at the center of the vapor cylinder for connecting to external pressure sensor located inside of the tester
    Pressure Sensor: Semiconductor type pressure sensor.
    Range: 0 to 196 kPa (2kgf/cm2)
    Linearity: <0.3% of the range
    Hysteresis: <0.3% of the range
    Display: LCD with back light
    Pressure Display Range: 0 to 200 kPa or 0 to 2 kgf/cm2
    Shaking: By "see-saw" movement with angular movement of +/-15 degrees and interval of 6 sec
    Bath Temperature Range: Ambient to 60°C
    Temp Control: Digital controller/display with PT-100 Sensor, Precision: +/-0.1°C
    Stirring: By propeller driven by motor
    Heater: Stainless sheathed heater 1.15kW
    Calibration: By connecting a Digital Manometer (optional) to the pressure sensor
    Safety Mechanism: Water level monitoring device for preventing overheating due to low water level
    Data Output: 1xRS-232C channel (for PC or Optional Printer)
    Dimension & Weight: 400W x 600D x 720H (mm), 50kg when dry, 85kg when filled with water
    Installation Site: Ambient temperature: 0 to 40°C
    Relative Humidity: Less than 90% (no condensation)
    Power Supply: AC100/120V or 220/240V 50/60Hz (set at the factory) 1.5 kW (max.)

    IQ/OQ/PQ Qualification: Yes, possible
  9. AVP-30D3

    Model: AVP-30D3
    Related Standards: ISO 3007, ASTM D323, IP69 etc.
    Type: Bench-top automated instrument. Automated continuous shaking of test cylinder by "seesaw" motion.
    Number Of Cylinders (Measurement Spots): 3
    Measuring Range: 0 to 196 kPa (2 kgf/cm2)
    Test Cylinders: Small size stainless steel cylinders with 66% in length and 31% in volume compared to the regular full size cylinders. The V/L ratio of 4 is the same as full size cylinder. A "Quick Coupler" is equipped at the center of the vapor cylinder for connecting to external pressure sensor located inside of the tester
    Pressure Sensor: Semiconductor type pressure sensor.
    Range: 0 to 196 kPa (2kgf/cm2)
    Linearity: <0.3% of the range
    Hysteresis: <0.3% of the range
    Display: LCD with back light
    Pressure Display Range: 0 to 200 kPa or 0 to 2 kgf/cm2
    Shaking: By "see-saw" movement with angular movement of +/-15 degrees and interval of 6 sec
    Bath Temperature Range: Ambient to 60°C
    Temp Control: Digital controller/display with PT-100 Sensor, Precision: +/-0.1°C
    Stirring: By propeller driven by motor
    Heater: Stainless sheathed heater 1.15kW
    Calibration: By connecting a Digital Manometer (optional) to the pressure sensor
    Safety Mechanism: Water level monitoring device for preventing overheating due to low water level
    Data Output: 1xRS-232C channel (for PC or Optional Printer)
    Dimension & Weight: 400W x 600D x 720H (mm), 50kg when dry, 85kg when filled with water
    Installation Site: Ambient temperature: 0 to 40°C
    Relative Humidity: Less than 90% (no condensation)
    Power Supply: AC100/120V or 220/240V 50/60Hz (set at the factory) 1.5 kW (max.)

    IQ/OQ/PQ Qualification: Yes, possible
  10. AVP-30D2

    Model: AVP-30D2
    Related Standards: ISO 3007, ASTM D323, IP69 etc.
    Type: Bench-top automated instrument. Automated continuous shaking of test cylinder by "seesaw" motion.
    Number Of Cylinders (Measurement Spots): 2
    Measuring Range: 0 to 196 kPa (2 kgf/cm2)
    Test Cylinders: Small size stainless steel cylinders with 66% in length and 31% in volume compared to the regular full size cylinders. The V/L ratio of 4 is the same as full size cylinder. A "Quick Coupler" is equipped at the center of the vapor cylinder for connecting to external pressure sensor located inside of the tester
    Pressure Sensor: Semiconductor type pressure sensor.
    Range: 0 to 196 kPa (2kgf/cm2)
    Linearity: <0.3% of the range
    Hysteresis: <0.3% of the range
    Display: LCD with back light
    Pressure Display Range: 0 to 200 kPa or 0 to 2 kgf/cm2
    Shaking: By "see-saw" movement with angular movement of +/-15 degrees and interval of 6 sec
    Bath Temperature Range: Ambient to 60°C
    Temp Control: Digital controller/display with PT-100 Sensor, Precision: +/-0.1°C
    Stirring: By propeller driven by motor
    Heater: Stainless sheathed heater 1.15kW
    Calibration: By connecting a Digital Manometer (optional) to the pressure sensor
    Safety Mechanism: Water level monitoring device for preventing overheating due to low water level
    Data Output: 1xRS-232C channel (for PC or Optional Printer)
    Dimension & Weight: 400W x 600D x 720H (mm), 50kg when dry, 85kg when filled with water
    Installation Site: Ambient temperature: 0 to 40°C
    Relative Humidity: Less than 90% (no condensation)
    Power Supply: AC100/120V or 220/240V 50/60Hz (set at the factory) 1.5 kW (max.)

    IQ/OQ/PQ Qualification: Yes, possible