Artikli 1161 do 1170 od ukupno 1652

  1. ASP-6

    Model: AAP-6
    Test Methods: ASTM D36, ASTM E28, EN 1427, IP 58, etc
    Type: Two-rings & two-balls
    Measuring Range: Ambient to 200?C (392?F )
    Temperature Sensor: PT-100 in stainless steel sheath
    Softening Point Detector: Light projector: LED; Light receiver: photo-diode
    Display: 5.7" color LCD with back light
    Heater: Nichrome coil heater: 1,000W @100V or 1,000W @220V
    Sequense Control: By an on-board microcomputer
    Test Mode: ASTM D36 water, ASTM D36 glycerin, EN 1427 water, EN 1427 glycerin
    Stirring: Magnetic stirring, selectable from 0 to 250 rpm
    I/O Port: 1x Ethernet for LIMS; 1x USB for Flash Memory or Keyboard; 1x RS-232C for LIMS / PC or Optional Printer
    Data Memory: Last 200 sets of test results
    Safety Mechanism: a) The sample falls on only one side and not on the other within the set temperature range, b) The sample does not fall on either side within the set upper limit temperature, c) Light projector or receiver is found defective, d) Temperature sensor is found defective, e) Temperature sensor is not placed in the right position, f) Built-in battery is found drained out, or g)Control computer runs away (no display)
    Size (WxDxH): 230 x 470 x 440 (mm)
    Weight: 15 kg
    Ambiental Conditions: RT: 10 to 40?C, RH: Less than 90% (no condensation)
    Power Supply: AC100/120 V or 220/240V 50/60Hz (set at the factory, specify when ordering) 1,500W ( max.)

    IQ/OQ/PQ Qualification: Yes, possible
  2. MPC-102A

    Model: MPC-102A
    Type:: Mini Pour Point(PP) and Cloud Point(CP) tester with sequential CP and PP measuring capability. Sample cooling and pre-heating by TED.
    Test Standards: ASTM D6749/D97, ISO 3016 (PP), ASTM D7683/D2500, ISO 3015 (CP)
    Specimen Volume: 4.5ml
    Cooling: Air cooling
    Measuring Range: -30°C to +51°C (in 25°C ambient) (*:Sample viscosity, etc. affects on lowest temperature of the measuring range.)
    Measurement Modes: Selectable from various modes. 1.CP mode (0.1 or 1.0 °C, selectable) 2.PP modes: Programmed by the user. Programmable parameters are: *Amount of applied air pressure for PP detection, to accommodate different sample types: L(low) for diesel fuels, H(high) for lube oils, VH(very high) and UH (ultra high) for residual fuels and similar samples. *Testing intervals: 1.0°C, 2.5°C, or 3.0°C (In total, 4x3=12 modes for PP.) 3.CP/PP modes: CP is determined and then PP. PP detection is programmable by the user with the same parameters as PP modes'. (12 modes in total.)
    Sample Automatic Pre-Heating: Automatic preheating at either +45°C or EPP+10°C. (EPP=Expected Pour Point)
    Display: Test parameters, EPP, bath temperature, sample temperature, PP, and CP displayed on VFD. Temperatures displayed in 0.1°C increments.
    EPP Setting: EPP (Expected Pour Point) needs to be set prior to test starts.
    Specimen Cup: Cylindrical glass test jar with 4.5ml sample volume.
    Sensors: Compound type sensor assembly for PP and CP. PP detected by air pressure method (patented). CP detected photo-electrically. Pt100 temperature sensors.
    Sample Cooling Rate: As standard, 4°C/min. till EPP+40°C, and 1°C/min. Thereafter, cooling profile is programmable.
    Safety Shutdown: As hot side of TED reaches 60°C while preheating, warning buzzer beeps and heating stops.
    Data Output: RS-232C 1 channel (for PC or Optional Printer)
    Data Strage: Last 50 test data are stored in RAM
    Power Requirements: 100, 120, 220, or 240VAC 0.5kW
    Dimensions (WxDxH) (mm) and Weight: 230mm x 480 x 385, 20kg

    IQ/OQ/PQ Qualification: Yes, possible
  3. PX85

    Model: PX85
    Kataloški broj: 30485340
    Odobren model (kod Direkcije za mere i dragocene metale): Da
    Kalibracija: Interna
    Kapacitet (g): 82
    Rezolucija (g): 0,00001
    Ponovljivost (STDEV) (g): 0,00002
    Linearnost (g): ± 0,0001
    Vreme stabilizacije (s): 10
    Osetljivost temperaturnog odstupanja (PPM/K): ± 0,8
    Tipična minimalna masa merenja prema USP (USP K=2, U=0,10%): 20 mg
    Optimizovana minimalna masa merenja (USP, U=0,10%, K=2) SRP≤0,41d*: 9 mg
    Jedinice merenja: Milligram, Gram, Kilogram, Ounce, Pound, Carat, Pennyweight, Ounce Troy, Grain, Newton, Hong Kong Tael, Singapore Tael, Taiwan Tael, Momme, Tical (MM), Mesghal, Tola (India), 1 Custom unit
    Aplikacije: Osnovno merenje mase, Brojanje komada, Procentulano merenje, Merenje životinja, Određivanje gustine
    Dimenzije merene ploče (Ø): 80 mm
    Napajanje: Ulaz: 100-240V; 200mA 50-60Hz 12-18VA, Izlaz: 12VDC 0,5A
    Dimenzije vage (Š x D x V): 209 x 321 x 309 mm
    Komunikacioni interfejsi: RS232 i USB
    Opseg radne temperature: 10°C do 30°C
    Neto težina: 4,5 kg
    Težina transportnog pakovanja: 7 kg
    Dimenzije transportnog pakovanja (Š x D x V): 507 x 387 x 531 mm

    IQ/OQ/PQ Kvalifikacija: Da, moguća je

    *: Vrednost SRP je standardna devijacija za n broj merenja (n≥10)
  4. PX125D

    Model: PX125D
    Kataloški broj: 30478196
    Odobren model (kod Direkcije za mere i dragocene metale): Da
    Kalibracija: Interna
    Kapacitet (g): 52/120
    Rezolucija (g): 0,00001/0,0001
    Ponovljivost (STDEV) (g): 0,00002/0,0001
    Linearnost (g): ± 0,0001
    Vreme stabilizacije (s): 10
    Osetljivost temperaturnog odstupanja (PPM/K): ± 0,8
    Tipična minimalna masa merenja prema USP (USP K=2, U=0,10%): 20 mg
    Optimizovana minimalna masa merenja (USP, U=0,10%, K=2) SRP≤0,41d*: 9 mg
    Jedinice merenja: Milligram, Gram, Kilogram, Ounce, Pound, Carat, Pennyweight, Ounce Troy, Grain, Newton, Hong Kong Tael, Singapore Tael, Taiwan Tael, Momme, Tical (MM), Mesghal, Tola (India), 1 Custom unit
    Aplikacije: Osnovno merenje mase, Brojanje komada, Procentulano merenje, Merenje životinja, Određivanje gustine
    Dimenzije merene ploče (Ø): 80 mm
    Napajanje: Ulaz: 100-240V; 200mA 50-60Hz 12-18VA, Izlaz: 12VDC 0,5A
    Dimenzije vage (Š x D x V): 209 x 321 x 309 mm
    Komunikacioni interfejsi: RS232 i USB
    Opseg radne temperature: 10°C do 30°C
    Neto težina: 4,5 kg
    Težina transportnog pakovanja: 7 kg
    Dimenzije transportnog pakovanja (Š x D x V): 507 x 387 x 531 mm

    IQ/OQ/PQ Kvalifikacija: Da, moguća je

    *: Vrednost SRP je standardna devijacija za n broj merenja (n≥10)
  5. ACL-2

    Model: ACL-2
    Type: Transmittance colorimeter for petroleum products by tri-stimulus method
    Conforming Standards: ASTM D6045, JIS K2580
    Color Series: Saybolt color (ASTM D6045/D156), ASTM color (ISO 6271, ASTM D6045/D1500), Platinum-Cobalt color (ISO 6271, ASTM D1209) Gardner color (ISO 4630, ASTM D1544)
    Light Source: Halogen bulb (12V 20W)
    Light Receiver: Fast response silicon photo cells
    Tri-Stimulus Filters: Colored glass filters, Wavelength range: 380-780nm
    Displayed Parameters: Saybolt color, L*a*b, ΔL*?Δa*?Δb*?ΔE*; ASTM color, X?Y?Z?DX?DY?DZ??D; Pt-Co color; YI; Gardner color
    Automatic Calibration: Single point or multi point calibration using calibration samples.
    Sample Cells: Cylindrical glass cell with caps. 100mm pass length for Saybolt color. 33mm pass length for ASTM, Pt-Co, Gardner color
    Display Module: Fluorescent display module, 256 x 64 dots
    Printer: Thermal printer with 80mm paper width
    Data Output: 1x RS-232C port (standard)
    Size And Weight: 400W(mm) x 400D(mm) x 190H(mm), 12.2Kg
    Power Consumption: AC 100-240V, 130VA

    IQ/OQ/PQ Qualification: Yes, possible
  6. RX-630SA

    Model: RX-630SA
    Test Standard: JIS K 2541-4, ISO 8754, ASTM D4294-03, etc.
    Sample: Kerosene, Naphtha, Gas oil, Crude oil, Base oil, etc.
    Measuring Range: 0 to 6 wt %
    Measuring Time: 10 to 990 sec, 1 to 99 times
    Precision: LOD (Limit of Detection) = 15 mg/kg; LOQ (limit of quantitation) = 50mg/kg
    Sample Changer: Carousel type 12 position (sample volume: approx. 3ml)
    X Ray Source: Small air - cooled X-ray tube rated 7kv - 0,2mA
    Sample Cell: Reusable 2 piece PTFE cup with disposable cell sheet
    Automatic Calibration: 2 points, 3 points, M auto (max 12 points) calibration
    Automatic Correction: C/H correction, Temperature correction, Barometric pressure correction
    Number Of Calibration Curve: 3
    Printer: Build-in dot matrix type, paper width: 57mm
    Data Output: 1x RS-232C
    Data Storage: Last 999 test results
    Safety: Cut off X-ray tube supply by interlock system when X-ray is leaked
    Ambiental Conditions: 10 to 30°C (with a temperature drift within 10°C in a day) Relative humidity: less than 80%
    Size (W x D x H) (mm): 555 x 555 x 262
    Weight (Kg): 27
    Power Supply: AC100 to 240V, 200VA, 50/60Hz

    IQ/OQ/PQ Qualification: Yes, possible
  7. RX-360SH

    Model: RX-360SH
    Type: Total sulfur analyzer for petroleum products by energy dispersive X-ray fluorescence method
    Conforming Standards: ISO 8754, ASTM D4294-03, etc.
    Number Of Test: One (1)
    Sample Volume: 3 - 5ml
    Measuring Range: 0-6,00wt%
    Repeatability: *ASTM D4294 designates the repeatability in the range (r). In terms of standard deviation, 5ppm (check PDF brochure)
    C/H Ratio Compensation: Automatic with 0.003wt% max of compensation error when a 1wt% sample is tested.
    Measuring Time: 10-990sec with a 10sec increment. 1-99 times.
    Calibration: Automatic two point calibration; Manual two point calibration; Automatic multiple-point calibration (up to 10 points); Manual multiple-point calibration (up to 10 points)
    X-Ray Source: X-ray tube operated at 7kV-0.15mA
    Sample Cup: 2-piece Teflon cup with disposable Mylar film
    Printer: Built-in impact dot matrix printer (paper roll width 57mm)
    Display: LCD (20 characters x 4 lines)
    X-Ray Leakage: 0.6 micro Sv/Hr or less on instrument surface
    Data Output: 1x RS-232C
    Oparating Temperature/Humidity: 10-30°C with a temperature drift within 10°C in a day. rH to be within 80%.
    Power Supply: DC12V (with the provided AC Adapter or optional 12VDC cord with lighter plug)
    Safety: Interlock mechanism against accidental X-ray leakage
    Dimensions/Weight: Test head: 420W x 350D x140H (mm)/11kg; AC Adapter: 50W x 115D x 25H (mm)/0.25kg

    IQ/OQ/PQ Qualification: Yes, possible
  8. AFP-102

    Model: AFP-102
    Conforming Standards: IP309, ASTM D6371, EN116 and JIS K2288
    Type: 1 test head.
    Specimen Volume: 45ml
    Measuring Range (Typical): RT to -60°C (The lowest temperature varies with the chiller liquid temperature and ambient temperature.)
    Sequence Control: By a built-in micro processor
    Display: By a fluorescence display (VFD) Temperatures displayed with 0.1°C increments
    Temperature Sensor: Pt-100
    Cfpp Detection: By means of a photo-electric detector consisting of an LED, photo transistor, and light guide (fiber optics). Upper and lower light guides are mounted on sliding type holder.
    Vacuum Regulator: Consists of a micro air pump, pressure switch, solenoid valve and a plastic bottle.
    Cooling And Heating (Needs Optional Chiller): By Peltier cells. The hot side of the Peltier cells needs to be cooled by external chiller.
    Temperature Control: By step (-34°C, -51°C and -67°C) or linear. The linear cooling rate can be programmed.
    Safety Features: a) Over cut: as hot side of TED reaches 60°C, warning buzzer beeps and stops. b) Self diagnostic: reported by an intermittent buzzer and a text message when any temperature sensor breaks down or the battery has drained out. c) System trouble: reported by a buzzer when the built-in microprocessor runs off.
    Data Output: 1x RS-232C (for PC or Optional Printer). 2nd set channel is optional.
    Power Requirements: 100 or 120VAC, 5A; 220 or 240VAC, 3A Please specify AC voltage when ordering.
    Dimensions And Weight: 350W x 550D x 480H mm, 27kg

    IQ/OQ/PQ Qualification: Yes, possible
  9. TCU-40B

    Model: TCU-40B
    Temperature Range: -40°C to Ambient
    Temperature Control: By digital display controller, ON/OFF control
    Temperature Stability: +/- 1°C
    Cooling Capacity: 87W@ -40°C, 158W@ -30°C, 212W@ -20°C (@50Hz)
    Pumping Capacity: Max Head: 2.0m, Max Flow Rate: 10lit/min, Force type
    Bath Volume: 7 litre
    EPP Setting: Current Leakage Breaker
    Power Source Voltage: AC 120V, 220V-240V *Specify when ordering
    Power Consumption: 700W max.
    External Dimensions: 320(W) x 590(D) x 725(H) mm
    Weight: 55kg (AC120V); 60kg (AC220-240V)
  10. MPC-602

    Model: MPC-602
    Type: Mini Pour Point(PP) and Cloud Point(CP) tester with 6 test heads in Bench-top package. With sequential CP and PP measurement capability. Sample cooling and pre-heating by Peltier modules with external cooling liquid.
    Test Standards: ASTM D6749/D97, ISO 3016(PP), ASTM D7683/D2500, ISO 3015 (CP)
    Specimen Volume: 4.5ml
    Measuring Range (Typical*): -65°C to +51°C to with cooling liquid of -35°C, -60°C to +51°C with cooling liquid of -25°C; -40°C to +51°C with tap water of 20°C, *:Sample viscosity, etc. affects on lowest temperature of the measuring range.
    Measurement Modes: Selectable from various modes. 1.CP mode (0.1 or 1.0°C, Selectable); 2.PP modes: Programmed by the user. Programmable parameters are: *Amount of applied air pressure for PP detection, to accommodate different sample types: L(low) for diesel fuels, H(high) for lube oils, VH(very high) and UH (ultra high) for residual fuels and similar samples. *Testing intervals: 1.0°C, 2.5°C, or 3.0°C (In total, 4x3=12 modes for PP.); 3.CP/PP modes: CP is determined and then PP. PP detection is programmable by the user with the same parameters as PP modes. (12 modes in total.)
    Sample Automatic Pre-Heating: Automatic preheating at either +45°C or EPP+10°C. (EPP = Expected Pour Point)
    EPP Setting: Test parameters, EPP, bath temperature, sample temperature, PP, and CP displayed on VFD. Temperatures displayed with 0.1°C increments.
    Printer: (built-in, thermal type). PP, CP, mode, EPP, etc. printed by thermal printer.
    Epp Setting: EPP(Expected Pour Point) needs to be set prior to test starts.
    Specimen Cup: Cylindrical glass test jar with 4.5ml sample volume.
    Sensors: Compound type sensor assembly for PP and CP. PP detected by air pressure method (patented). CP detected photo-electrically. PT100 temperature sensors.
    Sample Cooling Rate: As standard, 4°C/min. till EPP+40°C, and 1°C/min. Thereafter, cooling process is programmable.
    Safety Shutdown: As hot side of Peltier module reaches 60°C while preheating, warning buzzer beeps and heating stops.
    Data Output: RS-232C 1 channel
    Power Requirements: 100, 120, 220, or 240VAC 1.5kW
    Size (W x D x H): 800W x 550D x 850H, 100kg

    IQ/OQ/PQ Qualification: Yes, possible
Postavi Opadajući Pravac

   

Artikli 1161 do 1170 od ukupno 1652