  1. AAP-6

    Model: AAP-6
    Conforming Standards: ISO2977, ASTM D611, etc.
    Measuring Range: Ambient +20°C to 170°C, for bellow ambient temperature + 20°C, the optional water jacketed measuring cell and a cryostat must be used.
    Temeprature Sensor: Pt100 in stainless steel sheath
    Aniline Point Detector: Photo-electric cell with special detection circuitry
    Measuring Cell: Modified U-Tube type, vacuum jacketed glass cell with PTFE stopcock at the bottom for drainage.
    Display: 5,7" color LCD with LED backlight
    Heater: Immersion heater in stainless steel sheath: 20W
    Sequense Control: By an on-board microcomputer
    Test Mode: Sinle, repeat (2 kinds, average is reported to nearest 0,05°C), SPE and manual temp set
    I/O Port: 1x Ethernet for LIMS, 1x USB for Flash memory or keyboard, 1x RS-232C for PC or optional printer
    Safety Mechanism: Automatically shuts off and the problem is reported by buzzer and display in case: a) EAP+10°C or 170°C is reached, b) Temperature sensor is found defective, c) Light projector or receiver is found defective, d) Built in battery is found drained out, e) Control computer runs away (no display)
    Dimensions (W X D X H): 230 x 470 x 490 mm
    Weight: 14Kg
    Ambiental Conditions: 10 to 40°C, Relative Humidity less than 90%
    Power Supply: AC 100 to 240V; 50/60Hz; 125W max

    IQ/OQ/PQ Qualification: Yes, possible
  2. AKV-202

    Model: AKV-202
    Type: Bench top automatic KV measuring system with 2 viscometers in 1 bath
    Related Standards: ISO 3104, ASTM D445, IP71, etc.
    Viscometers: Modified Lanz-Zeitfuchs viscometers
    Measuring Range: 10,000 mm2 /s for automatic operation. (Range depends on viscometer.)
    Meniscus Detection: By photo-electric devices with fiber optics
    Timing: 0.00 - 999.99 sec
    Bath: Stainless Steel bath with drain, 18 liters
    Bath Heater: Sheathed heaters, 0.59kW x2
    Bath Lighting: Fluorescent light, 6W
    Bath Medium: Water (distilled or ion exchanged) for < 75°C, Colorless/transparent silicon oil (with PMCC flash point of 190°C at minimum and KV of 10-20mm2/s) for >= 75°C.
    Bath Temperature Controller: Temp: Preset at 6 points. Preset point can be set at any temp between 20 and 100°C; Precision: ±0.01°C
    Cleaning/Drying Viscometers: An automatic cycle consisting of draining sample, injecting chemicals, and drying with air. By vacuum; Chemicals: BTX for cleaning, Ethanol ?Bath Temp <80°C?for drying. (Ether or Ketone can not be used); Fume: Fume to be exhausted through trap and hose to outside
    Display: Test parameters, status, trouble, etc. displayed on fluorescence display module
    Printer: Thermal printer, 58mm of paper width
    Computer Output: RS-232C, 1 channel
    Safety: Alarms for gas, bath medium level, & bath overheat
    Power Requirements: 100, 120, 220 or 240VAC, 2 KW
    Dimension & Weight (Wxdxh): 530mm x 560mm x 930mm, 75kg

    IQ/OQ/PQ Qualification: Yes, possible
  3. AVP-30D4

    Model: AVP-30D4
    Related Standards: ISO 3007, ASTM D323, IP69 etc.
    Type: Bench-top automated instrument. Automated continuous shaking of test cylinder by "seesaw" motion.
    Number Of Cylinders (Measurement Spots): 4
    Measuring Range: 0 to 196 kPa (2 kgf/cm2)
    Test Cylinders: Small size stainless steel cylinders with 66% in length and 31% in volume compared to the regular full size cylinders. The V/L ratio of 4 is the same as full size cylinder. A "Quick Coupler" is equipped at the center of the vapor cylinder for connecting to external pressure sensor located inside of the tester
    Pressure Sensor: Semiconductor type pressure sensor.
    Range: 0 to 196 kPa (2kgf/cm2)
    Linearity: <0.3% of the range
    Hysteresis: <0.3% of the range
    Display: LCD with back light
    Pressure Display Range: 0 to 200 kPa or 0 to 2 kgf/cm2
    Shaking: By "see-saw" movement with angular movement of +/-15 degrees and interval of 6 sec
    Bath Temperature Range: Ambient to 60°C
    Temp Control: Digital controller/display with PT-100 Sensor, Precision: +/-0.1°C
    Stirring: By propeller driven by motor
    Heater: Stainless sheathed heater 1.15kW
    Calibration: By connecting a Digital Manometer (optional) to the pressure sensor
    Safety Mechanism: Water level monitoring device for preventing overheating due to low water level
    Data Output: 1xRS-232C channel (for PC or Optional Printer)
    Dimension & Weight: 400W x 600D x 720H (mm), 50kg when dry, 85kg when filled with water
    Installation Site: Ambient temperature: 0 to 40°C
    Relative Humidity: Less than 90% (no condensation)
    Power Supply: AC100/120V or 220/240V 50/60Hz (set at the factory) 1.5 kW (max.)

    IQ/OQ/PQ Qualification: Yes, possible
  4. AVP-30D3

    Model: AVP-30D3
    Related Standards: ISO 3007, ASTM D323, IP69 etc.
    Type: Bench-top automated instrument. Automated continuous shaking of test cylinder by "seesaw" motion.
    Number Of Cylinders (Measurement Spots): 3
    Measuring Range: 0 to 196 kPa (2 kgf/cm2)
    Test Cylinders: Small size stainless steel cylinders with 66% in length and 31% in volume compared to the regular full size cylinders. The V/L ratio of 4 is the same as full size cylinder. A "Quick Coupler" is equipped at the center of the vapor cylinder for connecting to external pressure sensor located inside of the tester
    Pressure Sensor: Semiconductor type pressure sensor.
    Range: 0 to 196 kPa (2kgf/cm2)
    Linearity: <0.3% of the range
    Hysteresis: <0.3% of the range
    Display: LCD with back light
    Pressure Display Range: 0 to 200 kPa or 0 to 2 kgf/cm2
    Shaking: By "see-saw" movement with angular movement of +/-15 degrees and interval of 6 sec
    Bath Temperature Range: Ambient to 60°C
    Temp Control: Digital controller/display with PT-100 Sensor, Precision: +/-0.1°C
    Stirring: By propeller driven by motor
    Heater: Stainless sheathed heater 1.15kW
    Calibration: By connecting a Digital Manometer (optional) to the pressure sensor
    Safety Mechanism: Water level monitoring device for preventing overheating due to low water level
    Data Output: 1xRS-232C channel (for PC or Optional Printer)
    Dimension & Weight: 400W x 600D x 720H (mm), 50kg when dry, 85kg when filled with water
    Installation Site: Ambient temperature: 0 to 40°C
    Relative Humidity: Less than 90% (no condensation)
    Power Supply: AC100/120V or 220/240V 50/60Hz (set at the factory) 1.5 kW (max.)

    IQ/OQ/PQ Qualification: Yes, possible
  5. AVP-30D2

    Model: AVP-30D2
    Related Standards: ISO 3007, ASTM D323, IP69 etc.
    Type: Bench-top automated instrument. Automated continuous shaking of test cylinder by "seesaw" motion.
    Number Of Cylinders (Measurement Spots): 2
    Measuring Range: 0 to 196 kPa (2 kgf/cm2)
    Test Cylinders: Small size stainless steel cylinders with 66% in length and 31% in volume compared to the regular full size cylinders. The V/L ratio of 4 is the same as full size cylinder. A "Quick Coupler" is equipped at the center of the vapor cylinder for connecting to external pressure sensor located inside of the tester
    Pressure Sensor: Semiconductor type pressure sensor.
    Range: 0 to 196 kPa (2kgf/cm2)
    Linearity: <0.3% of the range
    Hysteresis: <0.3% of the range
    Display: LCD with back light
    Pressure Display Range: 0 to 200 kPa or 0 to 2 kgf/cm2
    Shaking: By "see-saw" movement with angular movement of +/-15 degrees and interval of 6 sec
    Bath Temperature Range: Ambient to 60°C
    Temp Control: Digital controller/display with PT-100 Sensor, Precision: +/-0.1°C
    Stirring: By propeller driven by motor
    Heater: Stainless sheathed heater 1.15kW
    Calibration: By connecting a Digital Manometer (optional) to the pressure sensor
    Safety Mechanism: Water level monitoring device for preventing overheating due to low water level
    Data Output: 1xRS-232C channel (for PC or Optional Printer)
    Dimension & Weight: 400W x 600D x 720H (mm), 50kg when dry, 85kg when filled with water
    Installation Site: Ambient temperature: 0 to 40°C
    Relative Humidity: Less than 90% (no condensation)
    Power Supply: AC100/120V or 220/240V 50/60Hz (set at the factory) 1.5 kW (max.)

    IQ/OQ/PQ Qualification: Yes, possible
  6. ACR-6

    Model: ACR-M3
    Conforming Standards: ISO 6615, ASTM D189, IP 13, etc.
    Process Control: By built-in micro processor
    Heating Device: Nichrome coil heater, side and bottom, 1.3 kW@100V or 1.3 kW@220V
    Igniting Device: Pilot burner system. LP gas or city gas, Pilot burner is ignited manually before each test
    Flame Detector: Sample vapor is ignited and extinguished by detecting temperature by means of sheath type thermocouple
    Cooling Device: Forced air cooling by sirocco fan
    Time Monitor: Indicated by digital display: (a) Ignition time (from start to ignition); (b) Burning time (from ignition to heating start)
    Dimension: 250W x 360D x 190H (mm)
    Weight: 7.5 kg
    Dimension And Weight Of Oven Unit: 190Wx260Dx440H, 5.5kg
    Power Supply: AC100/120V or 220/240V 50/60Hz 1.5 kW (max.)
    Gas Supply: LP gas or Natural gas (Max. pressure <9.8kPa)

    IQ/OQ/PQ Qualification: Yes, possible
  7. ACR-M3

    Model: ACR-M3
    Conforming Standards: ISO 10370, ASTM D4530, etc.
    Measuring Range: 0.10 to 30 % (m/m)
    Coking Oven: with circular heating chamber, 85mm diameter by 105 mm deep, made of stainless steel
    Heater: Pipe type, 700W x 2, made of stainless steel
    Heating Range: Up to 500°C
    Process Controller: Digital Programmable Controller, model PC-935
    Thermocouple: JIS J-type (Fe-Constantan)
    Pressure Controller (2Nd Stage Regulator): Primary Pressure: 1400kPa max.; Control Range: 20 to 750kPa (usually 150kPa); Pressure Gauge: 0 to 0.7 MPa
    Flow Meter: 0.1 to 1 lit/min
    Flow Rate: Automatically regulated at 150 ml/min and 600 ml/min, According to ASTM D4530
    Condensate Trap: 200 ml vinyl laminated glass jar with threaded mouth
    Safety: The tester stops operation with the secondary pressure less than 80 kPa. Programmable controller cuts the heater output and sounds buzzer continuously when the oven is abnormally heated above 550°C. Further more, a separate circuit performs the same function when the oven heated above 600°C.
    Dimension & Weight: 350W x 390D x 460H (mm), 21kg
    Power Supply: AC100/120V or 220/240V 50/60Hz 1.6 kW(max)
    N2 Gas Supply: From cylinder or piping, 200-500 kPa; Inlet: 10 mm diameter, hose nipple (Consumption: Approx. 40 lit of N2 Gas/test)
    Exhaust: To be placed to a ventilator or fume hood; Exhaust Outlet: 10 mm diameter, hose nipple

    IQ/OQ/PQ Qualification: Yes, possible
  8. ACO-T602

    Model: ACO-T602
    Related Standards: ISO 2592, ASTM D92, IP 36, etc.
    Measuring Range: Ambient to 400°C
    Test Mode: ASTM D92 Flash, Flash + Fire, Fire point must be visually monitored
    Display: Fluorescent display tube (VFD module)
    Printer: Thermal type printer (provided)
    Temperatur Sensor: PT-100 in stainless steel sheath
    Flash Detection: Ionization between test cup and igniters (Patented)
    Heater: Nichrome Coil heater: 1kW@100V or 1.2kW@220V
    Ignition Source: Dual Electric Igniters (platinum coil)
    Cooling Device: Forced air cooling by sirocco fan
    Barometric Correction: By built-in barometric pressure sensor
    Data Output: RS-232C 1 channel
    Safety Mechanism: Fire containment lid which activates automatically to help putting out fire when ACO-T602 detects a specimen is burning up heavily. If flash is not detected until the temperature reaches EFP+30 oC or 400 oC, the test is terminated and cooling starts. Automatically shuts off and the problem is reported by buzzer and display, in case: (a) Temperature sensor is found defective, (b) Flash detector is found defective, (c) Thermofuse is blown (Also fire containment lid activates), (d) Built-in battery is found drained out, (e) Upper arm switch is found defective, (f) Lower arm switch is found defective, (g) Shutter open/close switch is found defective, or (h) Control computer runs away (no display)
    Dimension & Weight: Control unit: 230W x 455D x 110H (mm), 6kg; Test unit: 405W x 515D x 400H (mm), 33kg; Printer: 134W x 180D x 58H (mm), 0.6kg
    Installation Site: Ambient temperature: 0 to 40 oC; RH: Less than 90% (no condensation)
    Power Supply: Single Phase AC100/120V or 220/240V 50/60Hz, (set at the factory) 1.7kW(max.), One line must be grounded.

    IQ/OQ/PQ Qualification: Yes, possible
  9. ABL-8L

    Model: ABL-8L
    Type: All -in one, microprocessor controlled
    Test Standards: ISO 13736/ IP170, ISO 1516, ISO 1524
    Measuring Range: -30°C to +80°C at cooling medium of 10°C, 0°C to +110°C at cooling medium of 40°C
    Measurement Modes: ISO13736 Normal, ISO13736 SPE (search), ISO13736 Rapid, ISO1516, ISO1523, and User Custom
    Bath: Metal Block
    Sample Cooling/Heating: By Peltier Device
    Display: 5.7 inch (117 x 88mm) color LCD with LED back light
    Stirring: 0, 30 rpm (selectable)
    Temperature Sensor: PT-100 in stainless steel sheath
    Flash Detector: CRC Thermocouple
    Ignition Source: Gas ignition with automatic lighting or electric ignition. Interchangeable
    Barometric Correction: Automatic correction by built-in barometric pressure sensor
    I/O Port: 1x RS-232C (for PC or Optional Printer); 1x USB channel (for USB keyboard or USB Flash Memory)
    Safety Shutdown: Automatically shuts off and the problem is reported by buzzer and display, in case: (a) EFP+10 oC or 70 oC (ISO13736)110 oC(ISO1516,ISO1523) is reached, (b) temperature sensor is found defective, (c) flash detector is found defective, (d) thermofuse is blown, (e) electric Igniter is blown, (f) built-in battery is found drained out, (g) test cover is not set in place, (h)control computer runs away (no display)
    Gas Supply: (When Gas Ignition is used), LP gas or natural gas (Max. pressure:10kPa)
    Power Supply: 100/120VAC or 220/240 VAC, 50/60Hz
    Power Consumption: 250VA MAX.
    Electricity Consumption: 30Wh for 1 test (about 30 min), 11.34gCO2 (@ 0.378kgCO2/1kWh)
    Ambient Temp. Range: 10°C to 35°C
    Dimensions & Weight: 230mm (W) x 470mm (D) x 390mm (H) 16kg

    Requirements For Chiller Option For Abl-8L
    Type: Circulator with heating/cooling capacities. Open bath type.
    Temperature Range: 5°C to +40°C or wider
    Pump Capacity: Pressure:0.2bar minimum; Flow rate:2L/min minimum
    Cooling Capacity: 250W@10°C minimum
    Heater Capacity: 500W minimum
    Bath Volume: 3L minimum

    IQ/OQ/PQ Qualification: Yes, possible
  10. ABL-8A

    Model: ABL-8
    Type: All -in one, microprocessor controlled
    Test Standards: ISO 13736/ IP170, ISO 1516, ISO 1523
    Measuring Range: +10°C to +110°C at room temperature of 10 to 30°C
    Measurement Modes: ISO13736 Normal, ISO13736 SPE (search), ISO13736 Rapid, ISO1516, ISO1523, and User Custom
    Bath: Metal Block
    Sample Cooling/Heating: By Peltier Device
    Display: 5.7 inch (117 x 88mm) color LCD with LED back light
    Stirring: 0, 30 rpm (selectable)
    Temperature Sensor: PT-100 in stainless steel sheath
    Flash Detector: CRC Thermocouple
    Ignition Source: Gas ignition with automatic lighting or electric ignition. Interchangeable
    Barometric Correction: Automatic correction by built-in barometric pressure sensor
    I/O Port: 1x RS-232C (for PC or Optional Printer); 1x USB channel (for USB keyboard or USB Flash Memory)
    Safety Shutdown: Automatically shuts off and the problem is reported by buzzer and display, in case: (a) EFP+10 oC or 70 oC (ISO13736)110 oC(ISO1516,ISO1523) is reached, (b) temperature sensor is found defective, (c) flash detector is found defective, (d) thermofuse is blown, (e) electric Igniter is blown, (f) built-in battery is found drained out, (g) test cover is not set in place, (h)control computer runs away (no display)
    Gas Supply: (When Gas Ignition is used), LP gas or natural gas (Max. pressure:10kPa)
    Power Supply: 100/120VAC or 220/240 VAC, 50/60Hz
    Power Consumption: 250VA MAX.
    Electricity Consumption: 30Wh for 1 test (about 30 min), 11.34gCO2 (@ 0.378kgCO2/1kWh)
    Ambient Temp. Range: 10°C to 35°C
    Dimensions & Weight: 230mm (W) x 470mm (D) x 390mm (H) 16kg

    IQ/OQ/PQ Qualification: Yes, possible