  1. ATG-8W

    Model: ATG-8W
    Test Methods: ASTM D56, IP 304, JIS K2265-1
    Measuring Range: ambient to +95°C
    Ignition source: Gas flame or Electric Coil
    Temperature Sensor: PT-100 in stainless steel sheath
    Flash Detector: CRC Thermocouple
    Operating Environment: 10°C to 35°C
    Power consumption: 500W
    Size: 230(W) x 470(D) x 385(H) mm
    Net Weight: 17kg

    IQ/OQ/PQ qualification: Yes, possible
  2. ACO-T602

    Model: ACO-T602
    Related Standards: ISO 2592, ASTM D92, IP 36, etc.
    Measuring Range: Ambient to 400°C
    Test Mode: ASTM D92 Flash, Flash + Fire, Fire point must be visually monitored
    Display: Fluorescent display tube (VFD module)
    Printer: Thermal type printer (provided)
    Temperatur Sensor: PT-100 in stainless steel sheath
    Flash Detection: Ionization between test cup and igniters (Patented)
    Heater: Nichrome Coil heater: 1kW@100V or 1.2kW@220V
    Ignition Source: Dual Electric Igniters (platinum coil)
    Cooling Device: Forced air cooling by sirocco fan
    Barometric Correction: By built-in barometric pressure sensor
    Data Output: RS-232C 1 channel
    Safety Mechanism: Fire containment lid which activates automatically to help putting out fire when ACO-T602 detects a specimen is burning up heavily. If flash is not detected until the temperature reaches EFP+30 oC or 400 oC, the test is terminated and cooling starts. Automatically shuts off and the problem is reported by buzzer and display, in case: (a) Temperature sensor is found defective, (b) Flash detector is found defective, (c) Thermofuse is blown (Also fire containment lid activates), (d) Built-in battery is found drained out, (e) Upper arm switch is found defective, (f) Lower arm switch is found defective, (g) Shutter open/close switch is found defective, or (h) Control computer runs away (no display)
    Dimension & Weight: Control unit: 230W x 455D x 110H (mm), 6kg; Test unit: 405W x 515D x 400H (mm), 33kg; Printer: 134W x 180D x 58H (mm), 0.6kg
    Installation Site: Ambient temperature: 0 to 40 oC; RH: Less than 90% (no condensation)
    Power Supply: Single Phase AC100/120V or 220/240V 50/60Hz, (set at the factory) 1.7kW(max.), One line must be grounded.

    IQ/OQ/PQ Qualification: Yes, possible
  3. AVP-30D4

    Model: AVP-30D4
    Related Standards: ISO 3007, ASTM D323, IP69 etc.
    Type: Bench-top automated instrument. Automated continuous shaking of test cylinder by "seesaw" motion.
    Number Of Cylinders (Measurement Spots): 4
    Measuring Range: 0 to 196 kPa (2 kgf/cm2)
    Test Cylinders: Small size stainless steel cylinders with 66% in length and 31% in volume compared to the regular full size cylinders. The V/L ratio of 4 is the same as full size cylinder. A "Quick Coupler" is equipped at the center of the vapor cylinder for connecting to external pressure sensor located inside of the tester
    Pressure Sensor: Semiconductor type pressure sensor.
    Range: 0 to 196 kPa (2kgf/cm2)
    Linearity: <0.3% of the range
    Hysteresis: <0.3% of the range
    Display: LCD with back light
    Pressure Display Range: 0 to 200 kPa or 0 to 2 kgf/cm2
    Shaking: By "see-saw" movement with angular movement of +/-15 degrees and interval of 6 sec
    Bath Temperature Range: Ambient to 60°C
    Temp Control: Digital controller/display with PT-100 Sensor, Precision: +/-0.1°C
    Stirring: By propeller driven by motor
    Heater: Stainless sheathed heater 1.15kW
    Calibration: By connecting a Digital Manometer (optional) to the pressure sensor
    Safety Mechanism: Water level monitoring device for preventing overheating due to low water level
    Data Output: 1xRS-232C channel (for PC or Optional Printer)
    Dimension & Weight: 400W x 600D x 720H (mm), 50kg when dry, 85kg when filled with water
    Installation Site: Ambient temperature: 0 to 40°C
    Relative Humidity: Less than 90% (no condensation)
    Power Supply: AC100/120V or 220/240V 50/60Hz (set at the factory) 1.5 kW (max.)

    IQ/OQ/PQ Qualification: Yes, possible
  4. MPC-102L

    Model: MPC-102L
    Type:: Mini Pour Point(PP) and Cloud Point(CP) tester with sequential CP and PP measuring capability. Sample cooling and pre-heating by TED.
    Test Standards: ASTM D6749/D97, ISO 3016 (PP), ASTM D7683/D2500, ISO 3015 (CP)
    Specimen Volume: 4.5ml
    Cooling: Liquid Cooling
    Measuring Range: -40°C to +51°C with tap water of 20°C; -65°C to +51°C with cooling liquid of -35°C (*:Sample viscosity, etc. affects on lowest temperature of the measuring range.)
    Measurement Modes: Selectable from various modes. 1.CP mode (0.1 or 1.0 °C, selectable) 2.PP modes: Programmed by the user. Programmable parameters are: *Amount of applied air pressure for PP detection, to accommodate different sample types: L(low) for diesel fuels, H(high) for lube oils, VH(very high) and UH (ultra high) for residual fuels and similar samples. *Testing intervals: 1.0°C, 2.5°C, or 3.0°C (In total, 4x3=12 modes for PP.) 3.CP/PP modes: CP is determined and then PP. PP detection is programmable by the user with the same parameters as PP modes'. (12 modes in total.)
    Sample Automatic Pre-Heating: Automatic preheating at either +45°C or EPP+10°C. (EPP=Expected Pour Point)
    Display: Test parameters, EPP, bath temperature, sample temperature, PP, and CP displayed on VFD. Temperatures displayed in 0.1°C increments.
    EPP Setting: EPP (Expected Pour Point) needs to be set prior to test starts.
    Specimen Cup: Cylindrical glass test jar with 4.5ml sample volume.
    Sensors: Compound type sensor assembly for PP and CP. PP detected by air pressure method (patented). CP detected photo-electrically. Pt100 temperature sensors.
    Sample Cooling Rate: As standard, 4°C/min. till EPP+40°C, and 1°C/min. Thereafter, cooling profile is programmable.
    Safety Shutdown: As hot side of TED reaches 60°C while preheating, warning buzzer beeps and heating stops.
    Data Output: RS-232C 1 channel (for PC or Optional Printer)
    Data Strage: Last 50 test data are stored in RAM
    Power Requirements: 100, 120, 220, or 240VAC 0.5kW
    Dimensions (WxDxH) (mm) and Weight: 230mm x 480 x 385, 20kg

    IQ/OQ/PQ Qualification: Yes, possible
  5. RX-360SH

    Model: RX-360SH
    Type: Total sulfur analyzer for petroleum products by energy dispersive X-ray fluorescence method
    Conforming Standards: ISO 8754, ASTM D4294-03, etc.
    Number Of Test: One (1)
    Sample Volume: 3 - 5ml
    Measuring Range: 0-6,00wt%
    Repeatability: *ASTM D4294 designates the repeatability in the range (r). In terms of standard deviation, 5ppm (check PDF brochure)
    C/H Ratio Compensation: Automatic with 0.003wt% max of compensation error when a 1wt% sample is tested.
    Measuring Time: 10-990sec with a 10sec increment. 1-99 times.
    Calibration: Automatic two point calibration; Manual two point calibration; Automatic multiple-point calibration (up to 10 points); Manual multiple-point calibration (up to 10 points)
    X-Ray Source: X-ray tube operated at 7kV-0.15mA
    Sample Cup: 2-piece Teflon cup with disposable Mylar film
    Printer: Built-in impact dot matrix printer (paper roll width 57mm)
    Display: LCD (20 characters x 4 lines)
    X-Ray Leakage: 0.6 micro Sv/Hr or less on instrument surface
    Data Output: 1x RS-232C
    Oparating Temperature/Humidity: 10-30°C with a temperature drift within 10°C in a day. rH to be within 80%.
    Power Supply: DC12V (with the provided AC Adapter or optional 12VDC cord with lighter plug)
    Safety: Interlock mechanism against accidental X-ray leakage
    Dimensions/Weight: Test head: 420W x 350D x140H (mm)/11kg; AC Adapter: 50W x 115D x 25H (mm)/0.25kg

    IQ/OQ/PQ Qualification: Yes, possible
  6. APM-8

    Model: APM-8 / APM-8FC
    Test Methods: ISO 2719, ASTM D93, IP34 JIS K2265-3
    Measuring Range: Ambient to 370°C
    Ignition source: Gas flame or Electric Coil
    Temperature Sensor: PT-100 in stainless steel sheath
    Flash Detector: CRC Thermocouple
    Power consumption: 720W
    Size: 230(W) x 470(D) x 385(H) mm
    Net Weight: 17kg

    IQ/OQ/PQ kvalifikacija: Yes, possible
  7. ABL-8A

    Model: ABL-8
    Type: All -in one, microprocessor controlled
    Test Standards: ISO 13736/ IP170, ISO 1516, ISO 1523
    Measuring Range: +10°C to +110°C at room temperature of 10 to 30°C
    Measurement Modes: ISO13736 Normal, ISO13736 SPE (search), ISO13736 Rapid, ISO1516, ISO1523, and User Custom
    Bath: Metal Block
    Sample Cooling/Heating: By Peltier Device
    Display: 5.7 inch (117 x 88mm) color LCD with LED back light
    Stirring: 0, 30 rpm (selectable)
    Temperature Sensor: PT-100 in stainless steel sheath
    Flash Detector: CRC Thermocouple
    Ignition Source: Gas ignition with automatic lighting or electric ignition. Interchangeable
    Barometric Correction: Automatic correction by built-in barometric pressure sensor
    I/O Port: 1x RS-232C (for PC or Optional Printer); 1x USB channel (for USB keyboard or USB Flash Memory)
    Safety Shutdown: Automatically shuts off and the problem is reported by buzzer and display, in case: (a) EFP+10 oC or 70 oC (ISO13736)110 oC(ISO1516,ISO1523) is reached, (b) temperature sensor is found defective, (c) flash detector is found defective, (d) thermofuse is blown, (e) electric Igniter is blown, (f) built-in battery is found drained out, (g) test cover is not set in place, (h)control computer runs away (no display)
    Gas Supply: (When Gas Ignition is used), LP gas or natural gas (Max. pressure:10kPa)
    Power Supply: 100/120VAC or 220/240 VAC, 50/60Hz
    Power Consumption: 250VA MAX.
    Electricity Consumption: 30Wh for 1 test (about 30 min), 11.34gCO2 (@ 0.378kgCO2/1kWh)
    Ambient Temp. Range: 10°C to 35°C
    Dimensions & Weight: 230mm (W) x 470mm (D) x 390mm (H) 16kg

    IQ/OQ/PQ Qualification: Yes, possible
  8. AVP-30D2

    Model: AVP-30D2
    Related Standards: ISO 3007, ASTM D323, IP69 etc.
    Type: Bench-top automated instrument. Automated continuous shaking of test cylinder by "seesaw" motion.
    Number Of Cylinders (Measurement Spots): 2
    Measuring Range: 0 to 196 kPa (2 kgf/cm2)
    Test Cylinders: Small size stainless steel cylinders with 66% in length and 31% in volume compared to the regular full size cylinders. The V/L ratio of 4 is the same as full size cylinder. A "Quick Coupler" is equipped at the center of the vapor cylinder for connecting to external pressure sensor located inside of the tester
    Pressure Sensor: Semiconductor type pressure sensor.
    Range: 0 to 196 kPa (2kgf/cm2)
    Linearity: <0.3% of the range
    Hysteresis: <0.3% of the range
    Display: LCD with back light
    Pressure Display Range: 0 to 200 kPa or 0 to 2 kgf/cm2
    Shaking: By "see-saw" movement with angular movement of +/-15 degrees and interval of 6 sec
    Bath Temperature Range: Ambient to 60°C
    Temp Control: Digital controller/display with PT-100 Sensor, Precision: +/-0.1°C
    Stirring: By propeller driven by motor
    Heater: Stainless sheathed heater 1.15kW
    Calibration: By connecting a Digital Manometer (optional) to the pressure sensor
    Safety Mechanism: Water level monitoring device for preventing overheating due to low water level
    Data Output: 1xRS-232C channel (for PC or Optional Printer)
    Dimension & Weight: 400W x 600D x 720H (mm), 50kg when dry, 85kg when filled with water
    Installation Site: Ambient temperature: 0 to 40°C
    Relative Humidity: Less than 90% (no condensation)
    Power Supply: AC100/120V or 220/240V 50/60Hz (set at the factory) 1.5 kW (max.)

    IQ/OQ/PQ Qualification: Yes, possible
  9. ASP-6

    Model: AAP-6
    Test Methods: ASTM D36, ASTM E28, EN 1427, IP 58, etc
    Type: Two-rings & two-balls
    Measuring Range: Ambient to 200?C (392?F )
    Temperature Sensor: PT-100 in stainless steel sheath
    Softening Point Detector: Light projector: LED; Light receiver: photo-diode
    Display: 5.7" color LCD with back light
    Heater: Nichrome coil heater: 1,000W @100V or 1,000W @220V
    Sequense Control: By an on-board microcomputer
    Test Mode: ASTM D36 water, ASTM D36 glycerin, EN 1427 water, EN 1427 glycerin
    Stirring: Magnetic stirring, selectable from 0 to 250 rpm
    I/O Port: 1x Ethernet for LIMS; 1x USB for Flash Memory or Keyboard; 1x RS-232C for LIMS / PC or Optional Printer
    Data Memory: Last 200 sets of test results
    Safety Mechanism: a) The sample falls on only one side and not on the other within the set temperature range, b) The sample does not fall on either side within the set upper limit temperature, c) Light projector or receiver is found defective, d) Temperature sensor is found defective, e) Temperature sensor is not placed in the right position, f) Built-in battery is found drained out, or g)Control computer runs away (no display)
    Size (WxDxH): 230 x 470 x 440 (mm)
    Weight: 15 kg
    Ambiental Conditions: RT: 10 to 40?C, RH: Less than 90% (no condensation)
    Power Supply: AC100/120 V or 220/240V 50/60Hz (set at the factory, specify when ordering) 1,500W ( max.)

    IQ/OQ/PQ Qualification: Yes, possible
  10. TCU-40B

    Model: TCU-40B
    Temperature Range: -40°C to Ambient
    Temperature Control: By digital display controller, ON/OFF control
    Temperature Stability: +/- 1°C
    Cooling Capacity: 87W@ -40°C, 158W@ -30°C, 212W@ -20°C (@50Hz)
    Pumping Capacity: Max Head: 2.0m, Max Flow Rate: 10lit/min, Force type
    Bath Volume: 7 litre
    EPP Setting: Current Leakage Breaker
    Power Source Voltage: AC 120V, 220V-240V *Specify when ordering
    Power Consumption: 700W max.
    External Dimensions: 320(W) x 590(D) x 725(H) mm
    Weight: 55kg (AC120V); 60kg (AC220-240V)