  1. ACO-8

    Model: ACO-8
    Tip: Automatski instrument, mikroprocesorski kontrolisan
    Standardi: ISO 2592, ASTM D92, IP36
    Merni opseg: Od ambijentalne temperature do 400°C
    Metode merenja: ISO CRM, ISO Normal, ISO SPE, ISO Flash & Fire, ISO Skim*, ASTM Normal, ASTM SPE, ASTM Flash & Fire, ASTM Skim*, Meoda koju kreira korisnik (*: metodu radi samo model ACO-8AS)
    Grejač: Legura nikla, hroma i gvožđa: 800W@100V ili 800W@220V
    Hladnjak: Vazdušno forsirano hlađenje, "Sirocco" ventilator
    Displej: 5.7 inča (117 x 88mm) kolor LCD displej sa LED pozadinskim osvetljenjem
    Mehanizam za skidanje (samo verzija za asfalt): Teflonski noš rotira kako bi sa uzorka skinuo površinski film. Podešavaju se temperatura i vremenski interval u kome se skida film. Kada se ne koristi, može se skinuti
    Temperaturni senzor: PT-100 u oklopu od nerđajućeg čelika
    Detektor paljenja: Dupli jonizirajući prsten
    IQ/OQ/PQ kvalifikacije: Da, moguća
    Korekcija i kompenzacija rezultata: Automatska korekcija ugrađenim senzorom za pritisak.
    Ulazno-izlazni priključci: 1kom RS-232C (za PC ili opcioni printer), 1kom USB (za USB tastaturu ili USB Fleš memoriju)
    Sigurnosni mehanizmi: Automatsko gašenje pali alarm i indikaciju na displeju kada: (a) se postigne EFP+30°C ili temperatura od 400°C, (b) sistem detektuje neispravni termometar, (c) sistem detektuje neispravan detektor plamena, (d) sistem detektuje neispravan termalni osigurač (u tom trenutku se uključuje i poklopac koji zatvara posudu u kojoj nastane požar), (e) sistem detektuje praznu unutrašnju bateriju, (f) pokretni delovi nisu na početnoj poziciji, (g) sistem detektuje da ne radi kontrolni računar (ne radi displej)
    Dovod gasa: LPG ili neutralni gas (Max. pritisak:10kPa)
    Napajanje: 100/120VAC ili 220/240 VAC, 50/60Hz
    Snaga: 1000W MAX.
    Potrošnja: 160Wh za 1 test (oko 20 min), 60.48g CO2 (@ 0.378kgCO2/1kWh)
    Opseg ambijentalne temperature: 10°C do 35°C
    Dimenzije i težina: 230mm (D) x 470mm (Š) x 390mm (V) 16kg

    IQ/OQ/PQ kvalifikacije: Da, moguća
  2. ACR-M3

    Model: ACR-M3
    Conforming Standards: ISO 10370, ASTM D4530, etc.
    Measuring Range: 0.10 to 30 % (m/m)
    Coking Oven: with circular heating chamber, 85mm diameter by 105 mm deep, made of stainless steel
    Heater: Pipe type, 700W x 2, made of stainless steel
    Heating Range: Up to 500°C
    Process Controller: Digital Programmable Controller, model PC-935
    Thermocouple: JIS J-type (Fe-Constantan)
    Pressure Controller (2Nd Stage Regulator): Primary Pressure: 1400kPa max.; Control Range: 20 to 750kPa (usually 150kPa); Pressure Gauge: 0 to 0.7 MPa
    Flow Meter: 0.1 to 1 lit/min
    Flow Rate: Automatically regulated at 150 ml/min and 600 ml/min, According to ASTM D4530
    Condensate Trap: 200 ml vinyl laminated glass jar with threaded mouth
    Safety: The tester stops operation with the secondary pressure less than 80 kPa. Programmable controller cuts the heater output and sounds buzzer continuously when the oven is abnormally heated above 550°C. Further more, a separate circuit performs the same function when the oven heated above 600°C.
    Dimension & Weight: 350W x 390D x 460H (mm), 21kg
    Power Supply: AC100/120V or 220/240V 50/60Hz 1.6 kW(max)
    N2 Gas Supply: From cylinder or piping, 200-500 kPa; Inlet: 10 mm diameter, hose nipple (Consumption: Approx. 40 lit of N2 Gas/test)
    Exhaust: To be placed to a ventilator or fume hood; Exhaust Outlet: 10 mm diameter, hose nipple

    IQ/OQ/PQ Qualification: Yes, possible
  3. AKV-202

    Model: AKV-202
    Type: Bench top automatic KV measuring system with 2 viscometers in 1 bath
    Related Standards: ISO 3104, ASTM D445, IP71, etc.
    Viscometers: Modified Lanz-Zeitfuchs viscometers
    Measuring Range: 10,000 mm2 /s for automatic operation. (Range depends on viscometer.)
    Meniscus Detection: By photo-electric devices with fiber optics
    Timing: 0.00 - 999.99 sec
    Bath: Stainless Steel bath with drain, 18 liters
    Bath Heater: Sheathed heaters, 0.59kW x2
    Bath Lighting: Fluorescent light, 6W
    Bath Medium: Water (distilled or ion exchanged) for < 75°C, Colorless/transparent silicon oil (with PMCC flash point of 190°C at minimum and KV of 10-20mm2/s) for >= 75°C.
    Bath Temperature Controller: Temp: Preset at 6 points. Preset point can be set at any temp between 20 and 100°C; Precision: ±0.01°C
    Cleaning/Drying Viscometers: An automatic cycle consisting of draining sample, injecting chemicals, and drying with air. By vacuum; Chemicals: BTX for cleaning, Ethanol ?Bath Temp <80°C?for drying. (Ether or Ketone can not be used); Fume: Fume to be exhausted through trap and hose to outside
    Display: Test parameters, status, trouble, etc. displayed on fluorescence display module
    Printer: Thermal printer, 58mm of paper width
    Computer Output: RS-232C, 1 channel
    Safety: Alarms for gas, bath medium level, & bath overheat
    Power Requirements: 100, 120, 220 or 240VAC, 2 KW
    Dimension & Weight (Wxdxh): 530mm x 560mm x 930mm, 75kg

    IQ/OQ/PQ Qualification: Yes, possible
  4. MPC-102S

    Model: MPC-102S
    Test Standards: PP: ASTM D6749, ASTM D97, ISO 3016; CP: ASTM D7683, ASTM D2500, ISO 3015
    Specimen Volume: 4.5ml
    Measurement Modes: Selectable from various modes. 1.CP mode (0.1 or 1.0 °C intervals) 2.PP mode: Programmed by the user. Programmable parameters are: *Amount of applied air pressure for PP detection, to accommodate different sample types: L(low) for diesel fuels, H(high) for lube oils, VH(very high) and UH (ultra high) for residual fuels and similar samples. *Testing intervals: 1.0°C, 2.5°C, or 3.0°C (In total, 4x3=12 modes for PP.) 3.CP/PP modes: CP is determined and then PP. PP detection is programmable by the user with the same parameters as PP modes.
    Measuring Range: -65°C to +51°C
    Sample Automatic Pre-Heating: Automatic preheating at either +45°C or EPP+10°C. (EPP=Expected Pour Point)
    Display: Big digital display on VFD for showing real time parameters (sample temperature, bath temperature, test results).
    EPP Setting: EPP (Expected Pour Point) needs to be set prior to test starts.
    Specimen Cup: Cylindrical glass test jar with 4.5ml sample volume with reflex seal on the bottom for cloud point test.
    Sensors: Compound type sensor assembly for PP and CP. PP detected by air pressure method (patented). CP detected photo-electrically. PT100 temp. sensors.
    Sample Cooling Rate: As standard, 4°C/min. till EPP+40°C, and 1°C/min. Thereafter cooling profile is programmable.
    Safety Shutdown: As hot side of TED reaches 60°C while preheating, warning buzzer beeps and heating stops.
    Data Output: RS-232C 1 channel (for PC or Optional Printer)
    Power Supply: 100VAC to 240VAC 50/60Hz
    Power Consumption: 80 Wh for 1 test (about 1 hour), 30g CO2 (@0,378 Kg CO2 / 1000 Wh)
    Operating Ambiental Temperature: 10 to 35°C
    Size (W x D x H): 300 x 460 x 320 (mm)
    Weight: 11 Kg

    Bath Model: CB-80C
    Bath Temperature Range: -70°C to +80°C
    Bath Temperature Control: PID control with 2 points of revision functions
    Bath Size (W x D x H): 222 x 407 x 238 (mm)
    Bath Weight: 13 Kg

    IQ/OQ/PQ Qualification: Yes, possible
  5. RX-630SA

    Model: RX-630SA
    Test Standard: JIS K 2541-4, ISO 8754, ASTM D4294-03, etc.
    Sample: Kerosene, Naphtha, Gas oil, Crude oil, Base oil, etc.
    Measuring Range: 0 to 6 wt %
    Measuring Time: 10 to 990 sec, 1 to 99 times
    Precision: LOD (Limit of Detection) = 15 mg/kg; LOQ (limit of quantitation) = 50mg/kg
    Sample Changer: Carousel type 12 position (sample volume: approx. 3ml)
    X Ray Source: Small air - cooled X-ray tube rated 7kv - 0,2mA
    Sample Cell: Reusable 2 piece PTFE cup with disposable cell sheet
    Automatic Calibration: 2 points, 3 points, M auto (max 12 points) calibration
    Automatic Correction: C/H correction, Temperature correction, Barometric pressure correction
    Number Of Calibration Curve: 3
    Printer: Build-in dot matrix type, paper width: 57mm
    Data Output: 1x RS-232C
    Data Storage: Last 999 test results
    Safety: Cut off X-ray tube supply by interlock system when X-ray is leaked
    Ambiental Conditions: 10 to 30°C (with a temperature drift within 10°C in a day) Relative humidity: less than 80%
    Size (W x D x H) (mm): 555 x 555 x 262
    Weight (Kg): 27
    Power Supply: AC100 to 240V, 200VA, 50/60Hz

    IQ/OQ/PQ Qualification: Yes, possible
  6. ATG-8L

    Model: ATG-8L
    Test Methods: ASTM D56, IP 304, JIS K2265-1
    Measuring Range: -20°C to +95°C (with an optional chiller)
    Ignition source: Gas flame or Electric Coil
    Temperature Sensor: PT-100 in stainless steel sheath
    Flash Detector: CRC Thermocouple
    Operating Environment: 10°C to 35°C
    Power consumption: 250W
    Size: 230(W) x 470(D) x 385(H) mm
    Net Weight: 17kg

    IQ/OQ/PQ qualification: Yes, possible