  1. ABL-8L

    Model: ABL-8L
    Type: All -in one, microprocessor controlled
    Test Standards: ISO 13736/ IP170, ISO 1516, ISO 1524
    Measuring Range: -30°C to +80°C at cooling medium of 10°C, 0°C to +110°C at cooling medium of 40°C
    Measurement Modes: ISO13736 Normal, ISO13736 SPE (search), ISO13736 Rapid, ISO1516, ISO1523, and User Custom
    Bath: Metal Block
    Sample Cooling/Heating: By Peltier Device
    Display: 5.7 inch (117 x 88mm) color LCD with LED back light
    Stirring: 0, 30 rpm (selectable)
    Temperature Sensor: PT-100 in stainless steel sheath
    Flash Detector: CRC Thermocouple
    Ignition Source: Gas ignition with automatic lighting or electric ignition. Interchangeable
    Barometric Correction: Automatic correction by built-in barometric pressure sensor
    I/O Port: 1x RS-232C (for PC or Optional Printer); 1x USB channel (for USB keyboard or USB Flash Memory)
    Safety Shutdown: Automatically shuts off and the problem is reported by buzzer and display, in case: (a) EFP+10 oC or 70 oC (ISO13736)110 oC(ISO1516,ISO1523) is reached, (b) temperature sensor is found defective, (c) flash detector is found defective, (d) thermofuse is blown, (e) electric Igniter is blown, (f) built-in battery is found drained out, (g) test cover is not set in place, (h)control computer runs away (no display)
    Gas Supply: (When Gas Ignition is used), LP gas or natural gas (Max. pressure:10kPa)
    Power Supply: 100/120VAC or 220/240 VAC, 50/60Hz
    Power Consumption: 250VA MAX.
    Electricity Consumption: 30Wh for 1 test (about 30 min), 11.34gCO2 (@ 0.378kgCO2/1kWh)
    Ambient Temp. Range: 10°C to 35°C
    Dimensions & Weight: 230mm (W) x 470mm (D) x 390mm (H) 16kg

    Requirements For Chiller Option For Abl-8L
    Type: Circulator with heating/cooling capacities. Open bath type.
    Temperature Range: 5°C to +40°C or wider
    Pump Capacity: Pressure:0.2bar minimum; Flow rate:2L/min minimum
    Cooling Capacity: 250W@10°C minimum
    Heater Capacity: 500W minimum
    Bath Volume: 3L minimum

    IQ/OQ/PQ Qualification: Yes, possible
  2. AVP-30D3

    Model: AVP-30D3
    Related Standards: ISO 3007, ASTM D323, IP69 etc.
    Type: Bench-top automated instrument. Automated continuous shaking of test cylinder by "seesaw" motion.
    Number Of Cylinders (Measurement Spots): 3
    Measuring Range: 0 to 196 kPa (2 kgf/cm2)
    Test Cylinders: Small size stainless steel cylinders with 66% in length and 31% in volume compared to the regular full size cylinders. The V/L ratio of 4 is the same as full size cylinder. A "Quick Coupler" is equipped at the center of the vapor cylinder for connecting to external pressure sensor located inside of the tester
    Pressure Sensor: Semiconductor type pressure sensor.
    Range: 0 to 196 kPa (2kgf/cm2)
    Linearity: <0.3% of the range
    Hysteresis: <0.3% of the range
    Display: LCD with back light
    Pressure Display Range: 0 to 200 kPa or 0 to 2 kgf/cm2
    Shaking: By "see-saw" movement with angular movement of +/-15 degrees and interval of 6 sec
    Bath Temperature Range: Ambient to 60°C
    Temp Control: Digital controller/display with PT-100 Sensor, Precision: +/-0.1°C
    Stirring: By propeller driven by motor
    Heater: Stainless sheathed heater 1.15kW
    Calibration: By connecting a Digital Manometer (optional) to the pressure sensor
    Safety Mechanism: Water level monitoring device for preventing overheating due to low water level
    Data Output: 1xRS-232C channel (for PC or Optional Printer)
    Dimension & Weight: 400W x 600D x 720H (mm), 50kg when dry, 85kg when filled with water
    Installation Site: Ambient temperature: 0 to 40°C
    Relative Humidity: Less than 90% (no condensation)
    Power Supply: AC100/120V or 220/240V 50/60Hz (set at the factory) 1.5 kW (max.)

    IQ/OQ/PQ Qualification: Yes, possible
  3. MPC-102A

    Model: MPC-102A
    Type:: Mini Pour Point(PP) and Cloud Point(CP) tester with sequential CP and PP measuring capability. Sample cooling and pre-heating by TED.
    Test Standards: ASTM D6749/D97, ISO 3016 (PP), ASTM D7683/D2500, ISO 3015 (CP)
    Specimen Volume: 4.5ml
    Cooling: Air cooling
    Measuring Range: -30°C to +51°C (in 25°C ambient) (*:Sample viscosity, etc. affects on lowest temperature of the measuring range.)
    Measurement Modes: Selectable from various modes. 1.CP mode (0.1 or 1.0 °C, selectable) 2.PP modes: Programmed by the user. Programmable parameters are: *Amount of applied air pressure for PP detection, to accommodate different sample types: L(low) for diesel fuels, H(high) for lube oils, VH(very high) and UH (ultra high) for residual fuels and similar samples. *Testing intervals: 1.0°C, 2.5°C, or 3.0°C (In total, 4x3=12 modes for PP.) 3.CP/PP modes: CP is determined and then PP. PP detection is programmable by the user with the same parameters as PP modes'. (12 modes in total.)
    Sample Automatic Pre-Heating: Automatic preheating at either +45°C or EPP+10°C. (EPP=Expected Pour Point)
    Display: Test parameters, EPP, bath temperature, sample temperature, PP, and CP displayed on VFD. Temperatures displayed in 0.1°C increments.
    EPP Setting: EPP (Expected Pour Point) needs to be set prior to test starts.
    Specimen Cup: Cylindrical glass test jar with 4.5ml sample volume.
    Sensors: Compound type sensor assembly for PP and CP. PP detected by air pressure method (patented). CP detected photo-electrically. Pt100 temperature sensors.
    Sample Cooling Rate: As standard, 4°C/min. till EPP+40°C, and 1°C/min. Thereafter, cooling profile is programmable.
    Safety Shutdown: As hot side of TED reaches 60°C while preheating, warning buzzer beeps and heating stops.
    Data Output: RS-232C 1 channel (for PC or Optional Printer)
    Data Strage: Last 50 test data are stored in RAM
    Power Requirements: 100, 120, 220, or 240VAC 0.5kW
    Dimensions (WxDxH) (mm) and Weight: 230mm x 480 x 385, 20kg

    IQ/OQ/PQ Qualification: Yes, possible
  4. AFP-102

    Model: AFP-102
    Conforming Standards: IP309, ASTM D6371, EN116 and JIS K2288
    Type: 1 test head.
    Specimen Volume: 45ml
    Measuring Range (Typical): RT to -60°C (The lowest temperature varies with the chiller liquid temperature and ambient temperature.)
    Sequence Control: By a built-in micro processor
    Display: By a fluorescence display (VFD) Temperatures displayed with 0.1°C increments
    Temperature Sensor: Pt-100
    Cfpp Detection: By means of a photo-electric detector consisting of an LED, photo transistor, and light guide (fiber optics). Upper and lower light guides are mounted on sliding type holder.
    Vacuum Regulator: Consists of a micro air pump, pressure switch, solenoid valve and a plastic bottle.
    Cooling And Heating (Needs Optional Chiller): By Peltier cells. The hot side of the Peltier cells needs to be cooled by external chiller.
    Temperature Control: By step (-34°C, -51°C and -67°C) or linear. The linear cooling rate can be programmed.
    Safety Features: a) Over cut: as hot side of TED reaches 60°C, warning buzzer beeps and stops. b) Self diagnostic: reported by an intermittent buzzer and a text message when any temperature sensor breaks down or the battery has drained out. c) System trouble: reported by a buzzer when the built-in microprocessor runs off.
    Data Output: 1x RS-232C (for PC or Optional Printer). 2nd set channel is optional.
    Power Requirements: 100 or 120VAC, 5A; 220 or 240VAC, 3A Please specify AC voltage when ordering.
    Dimensions And Weight: 350W x 550D x 480H mm, 27kg

    IQ/OQ/PQ Qualification: Yes, possible
  5. AD-7

    Model: AD-7
    Standard Test Methods: ISO 3405, IP123/195, ASTM D86/D850/D1078, JIS K 2254
    Range: Selectable from 0°C to 300/450°C(fuel oil) or 0°C to 200/450°C (ASTM D850, D1078 with optional accessories)
    Display: TFT-LCD 10.4" Color Touch-Screen with universal design GUI
    Temperature sensor: Vapor: PT100, Heater: Thermocouple, Condenser: PT100, Receiver room: PT100
    Heater: 24V, 600W low mass and low voltage heater, spiral type
    Distillation Rate: 4.5 %/min at factory (Selectable from 2 to 9 % with 0.5 % increment)
    Test Mode: Up to 200 test modes can be recorded
    Safety features: Overheat protection. Warning device for fire.
    Correction: Loss correction and barometric correction
    Communication port: RS-232C, USB , Ethernet 1ch each.
    Dimensions: W430 x D520 x H710 mm
    Weight: 55 kg
    Power Source: AC100 V-240 V?50/60 Hz?1,500 W

    IQ/OQ/PQ kvalifikacija: Yes, possible
  6. ACO-8AS

    Model: ACO-8
    Tip: Automatski instrument, mikroprocesorski kontrolisan
    Standardi: ISO 2592, ASTM D92, IP36
    Merni opseg: Od ambijentalne temperature do 400°C
    Metode merenja: ISO CRM, ISO Normal, ISO SPE, ISO Flash & Fire, ISO Skim*, ASTM Normal, ASTM SPE, ASTM Flash & Fire, ASTM Skim*, Meoda koju kreira korisnik (*: metodu radi samo model ACO-8AS)
    Grejač: Legura nikla, hroma i gvožđa: 800W@100V ili 800W@220V
    Hladnjak: Vazdušno forsirano hlađenje, "Sirocco" ventilator
    Displej: 5.7 inča (117 x 88mm) kolor LCD displej sa LED pozadinskim osvetljenjem
    Mehanizam za skidanje (samo verzija za asfalt): Teflonski noš rotira kako bi sa uzorka skinuo površinski film. Podešavaju se temperatura i vremenski interval u kome se skida film. Kada se ne koristi, može se skinuti
    Temperaturni senzor: PT-100 u oklopu od nerđajućeg čelika
    Detektor paljenja: Dupli jonizirajući prsten
    IQ/OQ/PQ kvalifikacije: Da, moguća
    Korekcija i kompenzacija rezultata: Automatska korekcija ugrađenim senzorom za pritisak.
    Ulazno-izlazni priključci: 1kom RS-232C (za PC ili opcioni printer), 1kom USB (za USB tastaturu ili USB Fleš memoriju)
    Sigurnosni mehanizmi: Automatsko gašenje pali alarm i indikaciju na displeju kada: (a) se postigne EFP+30°C ili temperatura od 400°C, (b) sistem detektuje neispravni termometar, (c) sistem detektuje neispravan detektor plamena, (d) sistem detektuje neispravan termalni osigurač (u tom trenutku se uključuje i poklopac koji zatvara posudu u kojoj nastane požar), (e) sistem detektuje praznu unutrašnju bateriju, (f) pokretni delovi nisu na početnoj poziciji, (g) sistem detektuje da ne radi kontrolni računar (ne radi displej)
    Dovod gasa: LPG ili neutralni gas (Max. pritisak:10kPa)
    Napajanje: 100/120VAC ili 220/240 VAC, 50/60Hz
    Snaga: 1000W MAX.
    Potrošnja: 160Wh za 1 test (oko 20 min), 60.48g CO2 (@ 0.378kgCO2/1kWh)
    Opseg ambijentalne temperature: 10°C do 35°C
    Dimenzije i težina: 230mm (D) x 470mm (Š) x 390mm (V) 16kg

    IQ/OQ/PQ kvalifikacije: Da, moguća
  7. ACR-6

    Model: ACR-M3
    Conforming Standards: ISO 6615, ASTM D189, IP 13, etc.
    Process Control: By built-in micro processor
    Heating Device: Nichrome coil heater, side and bottom, 1.3 kW@100V or 1.3 kW@220V
    Igniting Device: Pilot burner system. LP gas or city gas, Pilot burner is ignited manually before each test
    Flame Detector: Sample vapor is ignited and extinguished by detecting temperature by means of sheath type thermocouple
    Cooling Device: Forced air cooling by sirocco fan
    Time Monitor: Indicated by digital display: (a) Ignition time (from start to ignition); (b) Burning time (from ignition to heating start)
    Dimension: 250W x 360D x 190H (mm)
    Weight: 7.5 kg
    Dimension And Weight Of Oven Unit: 190Wx260Dx440H, 5.5kg
    Power Supply: AC100/120V or 220/240V 50/60Hz 1.5 kW (max.)
    Gas Supply: LP gas or Natural gas (Max. pressure <9.8kPa)

    IQ/OQ/PQ Qualification: Yes, possible
  8. AAP-6

    Model: AAP-6
    Conforming Standards: ISO2977, ASTM D611, etc.
    Measuring Range: Ambient +20°C to 170°C, for bellow ambient temperature + 20°C, the optional water jacketed measuring cell and a cryostat must be used.
    Temeprature Sensor: Pt100 in stainless steel sheath
    Aniline Point Detector: Photo-electric cell with special detection circuitry
    Measuring Cell: Modified U-Tube type, vacuum jacketed glass cell with PTFE stopcock at the bottom for drainage.
    Display: 5,7" color LCD with LED backlight
    Heater: Immersion heater in stainless steel sheath: 20W
    Sequense Control: By an on-board microcomputer
    Test Mode: Sinle, repeat (2 kinds, average is reported to nearest 0,05°C), SPE and manual temp set
    I/O Port: 1x Ethernet for LIMS, 1x USB for Flash memory or keyboard, 1x RS-232C for PC or optional printer
    Safety Mechanism: Automatically shuts off and the problem is reported by buzzer and display in case: a) EAP+10°C or 170°C is reached, b) Temperature sensor is found defective, c) Light projector or receiver is found defective, d) Built in battery is found drained out, e) Control computer runs away (no display)
    Dimensions (W X D X H): 230 x 470 x 490 mm
    Weight: 14Kg
    Ambiental Conditions: 10 to 40°C, Relative Humidity less than 90%
    Power Supply: AC 100 to 240V; 50/60Hz; 125W max

    IQ/OQ/PQ Qualification: Yes, possible
  9. MPC-602

    Model: MPC-602
    Type: Mini Pour Point(PP) and Cloud Point(CP) tester with 6 test heads in Bench-top package. With sequential CP and PP measurement capability. Sample cooling and pre-heating by Peltier modules with external cooling liquid.
    Test Standards: ASTM D6749/D97, ISO 3016(PP), ASTM D7683/D2500, ISO 3015 (CP)
    Specimen Volume: 4.5ml
    Measuring Range (Typical*): -65°C to +51°C to with cooling liquid of -35°C, -60°C to +51°C with cooling liquid of -25°C; -40°C to +51°C with tap water of 20°C, *:Sample viscosity, etc. affects on lowest temperature of the measuring range.
    Measurement Modes: Selectable from various modes. 1.CP mode (0.1 or 1.0°C, Selectable); 2.PP modes: Programmed by the user. Programmable parameters are: *Amount of applied air pressure for PP detection, to accommodate different sample types: L(low) for diesel fuels, H(high) for lube oils, VH(very high) and UH (ultra high) for residual fuels and similar samples. *Testing intervals: 1.0°C, 2.5°C, or 3.0°C (In total, 4x3=12 modes for PP.); 3.CP/PP modes: CP is determined and then PP. PP detection is programmable by the user with the same parameters as PP modes. (12 modes in total.)
    Sample Automatic Pre-Heating: Automatic preheating at either +45°C or EPP+10°C. (EPP = Expected Pour Point)
    EPP Setting: Test parameters, EPP, bath temperature, sample temperature, PP, and CP displayed on VFD. Temperatures displayed with 0.1°C increments.
    Printer: (built-in, thermal type). PP, CP, mode, EPP, etc. printed by thermal printer.
    Epp Setting: EPP(Expected Pour Point) needs to be set prior to test starts.
    Specimen Cup: Cylindrical glass test jar with 4.5ml sample volume.
    Sensors: Compound type sensor assembly for PP and CP. PP detected by air pressure method (patented). CP detected photo-electrically. PT100 temperature sensors.
    Sample Cooling Rate: As standard, 4°C/min. till EPP+40°C, and 1°C/min. Thereafter, cooling process is programmable.
    Safety Shutdown: As hot side of Peltier module reaches 60°C while preheating, warning buzzer beeps and heating stops.
    Data Output: RS-232C 1 channel
    Power Requirements: 100, 120, 220, or 240VAC 1.5kW
    Size (W x D x H): 800W x 550D x 850H, 100kg

    IQ/OQ/PQ Qualification: Yes, possible
  10. ACL-2

    Model: ACL-2
    Type: Transmittance colorimeter for petroleum products by tri-stimulus method
    Conforming Standards: ASTM D6045, JIS K2580
    Color Series: Saybolt color (ASTM D6045/D156), ASTM color (ISO 6271, ASTM D6045/D1500), Platinum-Cobalt color (ISO 6271, ASTM D1209) Gardner color (ISO 4630, ASTM D1544)
    Light Source: Halogen bulb (12V 20W)
    Light Receiver: Fast response silicon photo cells
    Tri-Stimulus Filters: Colored glass filters, Wavelength range: 380-780nm
    Displayed Parameters: Saybolt color, L*a*b, ΔL*?Δa*?Δb*?ΔE*; ASTM color, X?Y?Z?DX?DY?DZ??D; Pt-Co color; YI; Gardner color
    Automatic Calibration: Single point or multi point calibration using calibration samples.
    Sample Cells: Cylindrical glass cell with caps. 100mm pass length for Saybolt color. 33mm pass length for ASTM, Pt-Co, Gardner color
    Display Module: Fluorescent display module, 256 x 64 dots
    Printer: Thermal printer with 80mm paper width
    Data Output: 1x RS-232C port (standard)
    Size And Weight: 400W(mm) x 400D(mm) x 190H(mm), 12.2Kg
    Power Consumption: AC 100-240V, 130VA

    IQ/OQ/PQ Qualification: Yes, possible